The Grid Meridian | 3.2kW Hybrid Solar Inverter with 80A MPPT Charger

Economisez 20%
East Supplier PlatformSKU: 1005008217036025-2KVA 12V-220-240V-france-No WIFI

Color: 2KVA 12V
Prix:
$402.55 $503.18

Taxes incluses Frais de port calculés au paiement

Stock:
57 en stock, prêts à être livrés

Description

A house that loses power for six hours is not an inconvenience. It is a broken routine, a spoiled freezer, a router that stops answering.

The Grid Meridian is built for the hours when the grid does not answer. It is a hybrid inverter, a solar charge controller and a battery charger in one chassis of 348 by 270 by 95 mm, weighing 5.8 kg. A pure sine wave output at 230 VAC, 50 or 60 Hz self-detecting, runs induction motors, laser printers and medical equipment without the buzz that modified sine units introduce.

Inside sits an 80 A MPPT tracker that accepts a PV string from 30 to 400 VDC, so a four-panel array can charge a 24 V bank directly without a separate controller. The LCD gives you the four settings that actually matter: charge current, AC input range, charger priority and output source priority. Lithium, gel, flooded and AGM profiles are selectable, and cold start brings the unit up from battery alone with no grid present.

Two ratings cover most households. The 12 V model delivers 2 kVA and 1.6 kW continuous; the 24 V model delivers 3.2 kVA and 3 kW. Both carry overload, over-temperature and short-circuit protection, and both accept an optional WiFi or GPRS dongle for remote monitoring.

Mounted on the wall beside the fuse board, it is a power room that keeps running while the street goes dark.


What It Does In A Power Cut

  • Pure sine wave output at 230 VAC with 50/60 Hz self-detection, safe for motors and sensitive electronics
  • 80 A MPPT solar charge controller with a 30 to 400 VDC PV input window, no external controller needed
  • 3.2 kVA / 3 kW continuous on the 24 V model, 2 kVA / 1.6 kW on the 12 V model
  • Multi-stage charging profiles for lithium, gel, flooded and AGM battery banks
  • LCD configuration of charge current, AC input range and AC/solar priority
  • Overload, over-temperature and short-circuit protection with automatic restart after AC returns
  • Cold start from battery, plus optional WiFi or GPRS monitoring dongle

Technical Specifications

  • ModelPOW-HVM2H-12V-N / POW-HVM3.2H-24V-N
  • Rated output2 kVA / 1.6 kW (12 V) - 3.2 kVA / 3 kW (24 V)
  • Output waveformPure sine wave, 230 VAC, 50/60 Hz self-detect
  • MPPT charge current80 A
  • PV input range30-400 VDC
  • Battery voltage12 VDC or 24 VDC
  • Battery chemistriesLithium, gel, flooded, AGM
  • Dimensions348 x 270 x 95 mm
  • Net weight5.8 kg
  • CertificationCE

Where It Earns Its Place

Cabins, workshops and rural homes run this unit as the primary supply, with the grid treated as a generator that visits occasionally. Off-grid builds use the 80 A tracker to keep a 24 V lithium bank topped up from a modest array. Small businesses put it on the freezer circuit, the POS terminal and the security system so a rolling blackout never touches revenue. Because the charger priority is configurable, a site with a weak but cheap grid can solar-charge by day and grid-charge only at night.

Questions From Installers

Q: Does it work without any solar panels connected?

Yes. The Grid Meridian charges from the AC input alone and behaves as a standard inverter-charger. Solar is an additional input, not a requirement.

Q: Can it charge a lithium battery bank?

The unit carries a dedicated lithium profile alongside gel, flooded and AGM. Set the profile in the LCD menu before first charge and confirm the absorption voltage against your battery datasheet.

Q: What size array can the 80 A MPPT take?

The tracker accepts 30 to 400 VDC on the PV input. An 80 A charge current at 24 V supports roughly 2 kW of array, which is more than the inverter's own 3 kW output needs during daylight hours.

Q: Will it run a well pump or an air conditioner?

Induction loads start at several times their running current. The 3 kW model starts most 1 HP pumps and small split units; for larger compressors, keep the surge figure of your load below the inverter's peak rating.

Q: Does the output frequency need to be set manually?

No. The inverter self-detects 50 or 60 Hz from the AC input, and the setting is visible and adjustable in the LCD menu if you run it without a grid reference.

Q: How fast does it switch over when the grid drops?

Transfer happens automatically within a fraction of a second, fast enough that most electronics ride through. Desktop computers with weak power supplies benefit from a small UPS in front of them.

Q: Is a WiFi dongle included?

The monitoring port is optional on this model. The inverter runs fully without it; the dongle adds remote read-out of charge state, load and fault history.

Q: What happens after an overload trip?

The unit shuts the output down, holds the fault on the LCD and restarts automatically once the AC input returns and the load is reduced. Clear the fault code list before sizing a bigger load onto it.

Q: Can two units run in parallel for more power?

The 3.2 kW model is a single-unit design. For higher demand, size up to a larger chassis rather than paralleling two of these.

Customer Reviews

Customer Reviews

Based on 3 reviews
67%
(2)
33%
(1)
0%
(0)
0%
(0)
0%
(0)
D
Desmond P.
Solid, needs a bigger manual

The hardware is doing exactly what it should on a 24 V gel bank. Cold start from battery alone worked the first time the grid dropped. My only complaint is the printed manual, which is thin on the lithium profile settings, so I used the battery datasheet instead.

T
Tamsin V.
Pure sine, no buzz

This replaced a modified sine unit that made the laser printer hum and the induction motor in the workshop run hot. Everything runs quietly now, and the fan only comes on under real load. Setting charger priority from the panel took me one evening with the manual open.

A
Alaric M.
Runs the whole cabin

Installed it with four 550 W panels and a 24 V lithium bank. The 80 A tracker means I did not need a separate charge controller, which saved a whole box on the wall and a set of cables. Two months in and the fridge, Starlink and the well pump all run from it, and the LCD makes it obvious what the system is doing at any moment.

Payment and Security

PayPal

Vos informations de paiement sont gérées de manière sécurisée. Nous ne stockons ni ne pouvons récupérer votre numéro de carte bancaire.

Estimer la livraison

You may also like

Recently Seen