Descrizione
Designed for start-ups
Super-X 5000-5L X1
FEATURES AND BENEFITS
Ideal for start-ups, product development and R&D labs.
Subcritical and supercritical parameters available in a small footprint.
Fully automated, energy efficient system.
Small footprintfaster extractions.
Multiple power options: 1-phase 230V (60 Hz) or3-phase 208V,230V, (50 or 60Hz).
Data record and
Start your extraction operation with The Super-X™5000-5LX1 and Super-X™ 5000-5LX2!
THE ADVANTAGE
Industry-first 2-year warranty.
Control panels are UL 508A Listed
Manufactured in our ASME certifiedfacility
95% CO2gas recovery, minimizing operational costs.
Open frame design and visual indication of valve positionsallow for easy assessment of flow paths and configuration.
Engineered performance with up to electrical energysavings over the competition.
Online parts store.
Comprehensive onsite and virtual training.
Free winterization classes for customers.
Veteran owned and operated.
24/7 free phone/virtual
Mid-Range
Designed for future expansion
Super-X 5000-5L X2 /Super-X 5000-25L X2 /Super-X 5000-25L X3
FEATURES AND BENEFITS
System designed to meet cGMP, with clean room separation design.
Extraction vessel designed with safety closures and special seals suitable for CO2duty and quick closures for separator vessels.
Modular steel frame for mounting of extraction vessels and all peripherals including controls.
Maximum operating pressure for extractors is 350 bar (5076 psi) and maximum temperature is 7
Maximum operating pressure for separator #1 is 130 bar (1885 psi) and 70 bar (1015 psi) for separator #2.
Additional water separator to trap the higher notes, and the most elusive terpenes.
Easy to use SCADA system with fully automatic and manual mode options.
System logs all data electronically for analysis.
Recycling of CO2for environmental and fiscal conservation.
Two stage safety with interlocked electronic controls and second stage mechanical safety.
Automated process valves with pneumatic controls.
High technology pressure regulation system consisting of controlled back pressure regulator.
Specially developed motorized CO2pump with controls for variable pressure and flow rate control.
Technical Data |
5000-5L-X1 |
5000-5L-X2 |
5000-25L-X2 |
5000-25L-X3 |
General |
||||
Footprint(m2) |
10 |
12 |
20 |
25 |
Height(m) |
1.8 |
1.8 |
4 |
4 |
Weight(Kg) |
300 |
350 |
2800 |
3000 |
Sound Pressure(db) |
45 |
45 |
60 |
60 |
Power |
||||
CO2 Pump(KW) |
2.2 |
2.2 |
5.5 |
7.5 |
Cooling Power(W) |
3400 |
3400 |
7500 |
11000 |
Heating Power(W) |
7000 |
7000 |
45000 |
50000 |
Extraction |
||||
Number of Vessel |
1 |
2 |
2 |
3 |
Vessel Size(L) |
5 |
5 |
25 |
25 |
Total Volume(L) |
5 |
10 |
50 |
75 |
Max.Pressure(psi) |
5000 |
5000 |
5000 |
5000 |
Extraction Temperature |
80℃ |
80℃ |
80℃ |
80℃ |
Separator |
||||
Number of Vessel |
2 |
2 |
2 |
3 |
Vessel Size(L) |
2.5 |
2.5 |
15 |
15 |
Total Volume(L) |
5 |
5 |
30 |
45 |
Max.Pressure(psi) |
3000 |
3000 |
3000 |
3000 |
Separator Temperature |
80℃ |
80℃ |
80℃ |
80℃ |
Recycler |
||||
Number of Vessel |
1 |
1 |
1 |
1 |
Vessel Size(L) |
5 |
5 |
20 |
20 |
Total Volume(L) |
5 |
5 |
20 |
20 |
Max.Pressure(psi) |
2000 |
2000 |
2000 |
2000 |
Transducers |
||||
Pressure Transducers |
6 |
7 |
7 |
11 |
Flow Transducers |
1 |
1 |
1 |
1 |
CO2 Sensor |
5000 |
5000 |
5000 |
5000 |
CO2 Flow Rate(kg/min) -Subcritical |
0.8kg/min |
0.8kg/min |
6.6kg/min |
10kg/min |
CO2 Flow Rate(kg/min) Supercritical |
0.5kg/min |
0.5kg/min |
5kg/min |
8kg/min |
Automation |
||||
Automatic control valve |
2 |
2 |
2 |
2 |
Touchscreen HMI/SCADA |
1 |
1 |
1 |
1 |
Safety Circuits |
||||
Burst Disc Safety Device |
3 |
6 |
6 |
9 |
Temperature Safety Device |
4 |
7 |
7 |
9 |
E-Stop |
1 |
1 |
2 |
2 |
CO2 Safety |
1 |
1 |
1 |
1 |
High Output:5000psi
Designed for supercritical high production
Super-X 5000-50L X3 /Super-X 5000-100L X3 /Super-X 5000-300L X3 /Super-X 5000-600L X3 /Super-X 5000-1000L X3 /Super-X 5000-1500L X3
FEATURES AND BENEFITS
System designed to meet cGMP, with clean room separation design.
Extraction vessel designed with safety closure.
Special seals suitable for CO2duty and quick closures for separator vessels.
Modular steel frame for mounting of extraction vessels and all peripherals including controls.
Maximum operating pressure for extractors is 350 bar (5076 psi) and maximum temperature is 7
Additional water separator to trap the higher notes, and the most elusive terpenes.
Easy to use SCADA system with fully automatic and manual mode options.
System logs all data electronically for analysis.
Recycling of CO2for environmental and fiscal conservation.
Two stage safety with interlocked electronic controls and second stage mechanical safety.
Automated process valves with pneumatic controls.
High technology pressure regulation system consisting of controlled back pressure regulator.
Specially developed motorized CO2pump with controls for variable pressure and flow rate control.
Technical Data |
Design Pressure (Mpa) |
Design Temperature (°C) |
Design Flow(L/H) |
Floor Area (m2) |
Height (m) |
50L×3 |
35-55 |
60~90 |
600 |
≤80 |
≤6 |
100L×3 |
35-55 |
60~90 |
1000 |
≤130 |
≤7 |
300L×3 |
35-55 |
60~90 |
2500 |
≤250 |
≤9 |
600L×3 |
35-55 |
60~90 |
4000 |
≤420 |
≤11 |
1000L×3 |
35-55 |
60~90 |
8000 |
≤500 |
≤13 |
1500L×3 |
35-55 |
60~90 |
8000 |
≤540 |
≤15 |
The system consists of three extraction vessels and two separator vessels, All purchased part are famous brands home and abroad, pressure vessels contacting with CO2 is packing up structure, the material of inner is SS304 or SS316L, automated control system, with tail-gas recover system and electric-heating system. |
Pagamento e Sicurezza
Le tue informazioni di pagamento vengono elaborate in modo sicuro. Non memorizziamo i dettagli della carta di credito né abbiamo accesso alle informazioni della tua carta di credito.