Descrizione
Carbon monoxide has no color, no smell and no direction. The Invisible Watch is a pocket-sized monitor that reads CO from 0 to 999 PPM while also logging temperature and relative humidity, on a body small enough to live in a glovebox, a tent pocket or a boiler room drawer. Three measurements, one screen, no subscription.
The specification that matters is accuracy. CO reads to plus or minus 10 PPM or five percent, temperature to plus or minus 1 C, humidity to plus or minus 5 percent RH. That is instrument-grade tolerance rather than the coarse threshold behavior of a household alarm, which is the difference between knowing a space is safe and knowing how quickly it is changing.
A honeycomb vent across the body lets the sensor see moving air without exposing it to grit, and the LCD shows all three readings at once so you are not cycling through menus while crouching next to a furnace. It runs on ordinary batteries, which is deliberate: a safety device that depends on a charging cable is a device that gets left at home.
You cannot smell it, see it, or feel it coming. You can measure it.
What Makes It Different
- ✦Measures carbon monoxide from 0 to 999 PPM alongside ambient temperature and relative humidity on one screen.
- ✦Instrument-grade tolerance of plus or minus 10 PPM or five percent on CO, rather than simple threshold triggering.
- ✦Compact body fits a glovebox, tool bag, tent pocket or boiler room drawer without taking up space.
- ✦Honeycomb vent design protects the sensor from grit while keeping it exposed to real airflow.
- ✦LCD shows all three readings simultaneously, so there is no menu cycling during an inspection.
- ✦Runs on standard batteries, so it works in a cabin, a basement or a vehicle with no power available.
- ✦CE marked and built for portable air quality checks rather than fixed wall installation only.
Technical Specifications
- ModelT9-PV19
- Gas measuredCarbon monoxide (CO)
- CO range0 to 999 PPM
- CO accuracyPlus or minus 10 PPM or 5 percent
- Temperature range0 to 50 C
- Temperature accuracyPlus or minus 1 C
- Humidity range0 to 99 percent RH
- Humidity accuracyPlus or minus 5 percent RH
- DisplayLCD, simultaneous readings
- PowerBatteries, not included
Where It Earns Its Place
Checking a basement before the heating season starts. Verifying that a wood stove, gas heater or generator is venting correctly in a cabin, garage or boat. Confirming air quality in a workshop where a laser cutter or a fuel burner runs. Monitoring a nursery or a bedroom in a rental with an old boiler. Taking a reading in a parked car or a camper before sleeping in it. It is the check you do before you trust a space, and the reading you take again a week later to see which way it is moving.
The EastSupplier Promise
Sourced directly from vetted manufacturing partners, inspected before dispatch, and priced without distributor layers. If the item arrives outside specification, we replace it or refund it. Every listing on this store is curated by a human buyer, not bulk-imported and abandoned.
Questions Buyers Actually Ask
Q: Does this replace a household CO alarm?
No. Use it as a diagnostic and spot-check instrument: it tells you the concentration now and how it is trending. A home should still have a certified alarm with an audible siren for unattended protection, especially near sleeping areas.
Q: What counts as a dangerous CO reading?
Any sustained reading above 30 to 35 PPM indoors warrants opening windows and finding the source. Above 100 PPM, leave the space. This instrument reports concentration, not medical advice, so treat symptoms like headache and dizziness as a reason to get out regardless of the number.
Q: How accurate is the CO sensor?
The specification is plus or minus 10 PPM or five percent of reading, whichever is greater. That is precise enough to detect a slow rise over days, which is the pattern that a simple alarm will not show you.
Q: How often should it be calibrated?
Sensors drift over years rather than months. For occasional household checks, an annual comparison against a known-good meter near a gas appliance is enough. For commercial or professional use, follow your own calibration schedule.
Q: What batteries does it use?
Standard cell batteries, not included so they arrive fresh. Fit the cells and the unit powers on within a few seconds, then let it settle in the space for a minute before reading.
Q: Can I use it while driving?
Yes, it is useful for checking cabin air on long trips and for spotting an exhaust leak early. Keep it on a vent or a cup holder rather than in direct sun, because the temperature sensor will read the dashboard rather than the cabin.
Q: Does it store readings over time?
This model displays live readings rather than logging to memory. Note the values at intervals if you are tracking a slow trend, which is the practical approach for seasonal checks.
Q: Will humidity affect the CO reading?
The three sensors are separate and compensated, so normal household humidity does not disturb the CO measurement. In condensing conditions, let the unit reach room temperature before taking a reading.
Q: Is it suitable for a commercial boiler room?
It is a useful portable check for technicians moving between rooms. For continuous unattended monitoring in a plant room, use fixed detectors wired to an alarm, and treat this as the instrument in your bag rather than the one on the wall.






Customer Reviews