{"product_id":"1kw-2kw-solar-grid-tie-inverter-for-solar-panel-battery-1000w-2000w-limiter-for-pv-power-dc-22-65v45-90v-ac-110v-120v-220v-230v","title":"1KW 2KW Solar Grid Tie Inverter for Solar Panel Battery 1000W 2000W Limiter for PV Power DC 22-65V45-90V AC 110V 120V 220V 230V","description":"\u003ch1\u003eSPECIFICATIONS\u003c\/h1\u003e\u003cp\u003e\u003cspan\u003eBrand Name\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eTINGEN\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eCertification\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eCE\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eHigh-concerned chemical\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eNone\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eIs Smart Device\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eYes\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eModel Number\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eSUN1000G2 \/ 2000G2\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eOrigin\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eMainland China\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eOutput Current\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e10A\/20A\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eOutput Frequency\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e55Hz-63Hz\/ 45Hz-53Hz\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eOutput Power\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e0-2000W\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eOutput Type\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eSINGLE\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eWeight\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e5kg\/7kg\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eis_customized\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eYes\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style='background-color:rgba(251,158,0,255);font-size:18px;font-family:\"times new roman\", times, serif'\u003e\u003cspan style='background-color:rgba(251,158,0,255);font-size:22px;font-family:\"times new roman\", times, serif'\u003eImportant notice: since the AC utility voltage always come to too high some moment at night especially in the middle night, we strongly suggest you to add a voltage regulator between the inverter AC output side and the Grid tie utility to avoid high grid tie voltage to damage the inverter AC side. We have meet several of this issue. Thank you！\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cbr\u003e\u003cbr\u003e\u003cp style=\"text-align:center\" align=\"center\"\u003e\u003cspan style=\"font-size:22px\"\u003e1KW 2KW Solar Grid Tie Inverter for Solar Panel Battery 1000W 2000W Limiter for PV Power DC 22-65V45-90V AC 110V 120V 220V 230V\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp style=\"text-align:center\" align=\"center\"\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/S2cdf7674a49c4f698ee762bceabc7c4aW.png\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/Sfeb4c0d704d541e2b229b94b406d7c18j.png\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/S96af5946a8d346dfa735e65a758e0683H.png\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/Sb7f9f1cf64564cce867205e3088028f3E.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cdiv\u003e\n\u003cspan style=\"color:rgb(244, 78, 59);font-size:26px;font-family:ArialMT\"\u003e\u003cspan style=\"color:rgb(244, 78, 59);font-size:26px;font-family:Arial-BoldMT\"\u003e\u003cstrong\u003eNew Time Setting Function\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color:rgb(244, 78, 59);font-size:26px;font-family:Arial-BoldMT\"\u003e\u003cspan style=\"color:rgb(244, 78, 59);font-size:26px;font-family:ArialMT\"\u003e: (60-110V input type not with this function)\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003e\u003cspan style=\"color:rgb(104, 188, 0);font-size:26px;font-family:ArialMT\"\u003e\u003cspan style=\"color:rgb(104, 188, 0);font-size:26px;font-family:Arial-BoldMT\"\u003eSave the setting after you reconﬁgure the working mode or backlight setting.\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"color:rgb(34, 31, 31);font-size:20px;font-family:ArialMT\"\u003eIf you want to control the work time of the inverter, you need to set the work time controller page. If you haven’t selected any of these four options, then the work time controller function will be disabled.If you have selected any of these four options, the selected options will be available, the inverter will work from the start time(left two columns, HH-MM) to stop time(right two columns, HH-MM). The inverter will stop to produce any power at other time that has not been selected.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cp\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/Sed5deb48e05544e0b5484103e9323c23V.png\" slate-data-type=\"image\"\u003e\u003cbr\u003e\u003c\/p\u003e\u003ch3\u003e\u003cspan style=\"font-size:18px\"\u003eWhy we produced the GRID TIE INVERTER WITH LIMITER ?\u003c\/span\u003e\u003c\/h3\u003e\u003cp\u003e\u003cspan style=\"font-size:18px\"\u003e\u003cspan style='font-family:\"times new roman\", times, serif'\u003e\u003cspan style=\"color:rgb(0, 112, 192)\"\u003eIt is in response to the overwhelming clamor from our customers for a product that can control the amount of power that the grid tie inverters (GTI) can generate so that the amount of excess power produced by the solar panels are  reduced to insignificant levels, if not eliminated --- because in some countries,the producer pays for the excess power it gives to the distribution grid. This is because the electric power meters (the one provided by the electricity provider in the area) are not aware of the direction of power flow. In other words it only adds even if  power is exported to the grid, thus, the consumers will be charged for power even if it is given to the grid, and this is the problem\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003ch3\u003e\u003cspan style=\"font-size:18px\"\u003eThis is the 2nd generation grid tie inverter with limiter.\u003c\/span\u003e\u003c\/h3\u003e\u003cp\u003e\u003cspan style=\"font-size:18px\"\u003e\u003cspan style='font-family:\"times new roman\", times, serif'\u003e\u003cspan style=\"color:rgb(0, 112, 192)\"\u003eWith the 2nd generation GTIL,we integrated the limit function inside the GTI-We call this internal limiter.In this way,No additional limiter module is needed,reduced customer’s cost,more easier for installation.But in case customer install inverter far away from the main circuit breaker,we also enable the 2nd GTIL work with stand-alone limiter,we call this-external limiter.For sure,the inverter can work under normal Grid tie-no limit mode,just set on the nice LCD and save your setting.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003ch3\u003e\u003cspan style=\"color:rgb(0, 0, 0)\"\u003e\u003cspan style=\"font-size:18px\"\u003eNew upgraded firmware enable battery or solar limiter current and power model.\u003c\/span\u003e\u003c\/span\u003e\u003c\/h3\u003e\u003cdiv\u003e\u003cspan style=\"font-size:18px\"\u003e\u003cspan style='font-family:\"times new roman\", times, serif'\u003e\u003cspan style=\"color:rgb(0, 112, 192)\"\u003eUser can set the maximum output power of inverter , this can make the inverter work at cooler contition as user want and extend the lifespan of the inverter .\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:18px\"\u003e\u003cspan style='font-family:\"times new roman\", times, serif'\u003e\u003cspan style=\"color:rgb(0, 112, 192)\"\u003eUser can set kick in\/off voltage of the inverter which can flexible using with battery bank depend on users mind and can prevent battery bank from over discharged .\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px\"\u003eTechnical Data\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003cp\u003e\u003cimg src=\"http:\/\/ae01.alicdn.com\/kf\/HTB1Yo2Nb8DH8KJjSszcq6zDTFXaI.jpg?size=154240\u0026amp;height=812\u0026amp;width=871\u0026amp;hash=9328989d61664e31af858eb31cd57aaa\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/S95ec1dedcf624c17b8f3e68e14a0a60cs.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/S8cab60650aad45a3a13eac49bde2beceq.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003ch2\u003e\u003cspan style=\"font-size:20px\"\u003e\u003cspan style=\"color:rgb(255, 0, 0)\"\u003e\u003cstrong\u003e\u003cspan style='font-family:\"times new roman\", times, serif'\u003eHow to choose the inverter  :\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-size:18px\"\u003e\u003cspan style='font-family:\"times new roman\", times, serif'\u003e\u003cspan style=\"color:rgb(0, 112, 192)\"\u003e1. About input voltage :\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:18px\"\u003e\u003cspan style='font-family:\"times new roman\", times, serif'\u003e\u003cspan style=\"color:rgb(0, 112, 192)\"\u003eThe 22-65V model inverter will start up at 25V, after starting, the inverter can work in 22V-65V .\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:18px\"\u003e\u003cspan style='font-family:\"times new roman\", times, serif'\u003e\u003cspan style=\"color:rgb(0, 112, 192)\"\u003eVmp 30v-60v Solar panels connected in Parallel suggested, for example : 4 pcs 200-260w (Vmp 31v solar panels in parallel ).\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:18px\"\u003e\u003cspan style='font-family:\"times new roman\", times, serif'\u003e\u003cspan style=\"color:rgb(0, 112, 192)\"\u003ethe 45-90V model inverter will start up at 49.5V, after starting, the inverter can work in 45V-90V.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:18px\"\u003e\u003cspan style='font-family:\"times new roman\", times, serif'\u003e\u003cspan style=\"color:rgb(0, 112, 192)\"\u003eVmp 50v-90v Solar panels in parallel suggested ; for Vmp 25V-45v solar panels , we suggest 2 panels in series , the total voltage will be 50V-90V , then connect 2 or more groups in parallel .  for example : 2 pcs 200-260w (Vmp 31v ) connected in series , 2 groups in parallel .  Save 2 connectors .\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/HTB19ZsTNFXXXXafapXXq6xXFXXXK\/112074412\/HTB19ZsTNFXXXXafapXXq6xXFXXXK.jpg?size=4487\u0026amp;height=22\u0026amp;width=800\u0026amp;hash=647cb1c78f856f75de049f59daa1c09a\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\u003ch2\u003e\u003cspan style=\"color:rgb(255, 0, 0)\"\u003e\u003cspan style=\"font-size:20px\"\u003e\u003cspan style=\"font-family:tahoma, geneva, sans-serif\"\u003eHow to use the grid tie inverter ?\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/h2\u003e\u003cp\u003e\u003cbr\u003e\u003cimg width=\"800\" height=\"auto\" src=\"https:\/\/ae01.alicdn.com\/kf\/S8427adbba0024d80ab3ca11b1c2765e1m.png\" slate-data-type=\"image\"\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"color:rgb(0, 112, 192);font-size:20px;font-family:tahoma, geneva, sans-serif\"\u003e1 unit inverter installation \/ more units inverters in parallel . the inverter AC output can be connected in the AC plug of grid in the house .\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003ch3\u003e2-1. Using Grid Tie Inverter With Limiter Model\u003c\/h3\u003e\u003cp\u003e\u003cimg width=\"800\" height=\"492\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sef3b2d43124444d7a2e890bb48ca5688q.png\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style='font-size:16px;font-family:\"times new roman\", times, serif'\u003e2.1 The Grid Tie Inverter with Limiter delivers only the power needed by the load and prevents delivering excess power hence avoids excess power in going back to the Grid.\u003c\/span\u003e\u003c\/p\u003e\u003cdiv\u003e\n\u003cp\u003e\u003cspan style='font-family:\"times new roman\", times, serif'\u003e\u003cspan style=\"font-size:16px\"\u003e2.2 The heart of the Grid Tie Inverter with Limiter is the Limiter Module (LM). The LM continuously sampled the power needed by the load through the current sensor connected after the Main Circuit Breaker. The LM then will process the signal. It then sends signal to Grid Tie Inverter how much power to deliver to the load in real time.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style='font-family:\"times new roman\", times, serif'\u003e\u003cspan style=\"font-size:16px\"\u003e2.3 The user, after installing and connecting the GTIL correctly, need not do anything and the unit will do its work automatically.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003e\u003c\/h3\u003e\u003ch3\u003e\u003cspan style=\"font-size:18px\"\u003e\u003cspan style=\"color:rgb(0, 112, 192)\"\u003e3. Installation of GTIL With Internal Limiter\u003c\/span\u003e\u003c\/span\u003e\u003c\/h3\u003e\u003cp\u003e\u003cimg width=\"800\" height=\"526\" src=\"https:\/\/ae01.alicdn.com\/kf\/Scded3eb4f3cc46e98b4c5720a1612eb8r.png\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style='font-size:16px;font-family:\"times new roman\", times, serif'\u003e3.1 This installation is not require an additional limiter module,Installation is much easier.Clamp the current sensor cable to the hot wire to measure the current,the internal limiter will auto detect the load power and control the inverter output power,excess power will be well controlled.\u003c\/span\u003e\u003c\/p\u003e\u003cdiv\u003e\n\u003cp\u003e\u003cspan style='font-family:\"times new roman\", times, serif'\u003e\u003cspan style=\"font-size:16px\"\u003e3.2 External protective device including dc and ac SPD(Surge protection device),dc and ac breaker,etc is recommended to installed in the system.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003ch3\u003e\u003cspan style=\"font-size:18px\"\u003e\u003cspan style=\"color:rgb(0, 112, 192)\"\u003e4.Limiter Setting on the LCD of the inverter:\u003c\/span\u003e\u003c\/span\u003e\u003c\/h3\u003e\u003cdiv\u003e\n\u003cp\u003e\u003cspan style='font-family:\"times new roman\", times, serif'\u003e\u003cspan style=\"font-size:16px\"\u003eThe GTIL include three working mode:\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style='font-family:\"times new roman\", times, serif'\u003e\u003cspan style=\"font-size:16px\"\u003eWork as normal GTI without power limitation.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style='font-family:\"times new roman\", times, serif'\u003e\u003cspan style=\"font-size:16px\"\u003eWork under Internal limiter mode\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style='font-family:\"times new roman\", times, serif'\u003e\u003cspan style=\"font-size:16px\"\u003eWork under External limiter mode,\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style='font-family:\"times new roman\", times, serif'\u003e\u003cspan style=\"font-size:16px\"\u003ePls make your setting on the LCD and save it,details setting operation,pls read the GTI manual.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003cp\u003e\u003cbr\u003e\u003cimg width=\"750\" height=\"auto\" src=\"https:\/\/ae01.alicdn.com\/kf\/S5658febcb2bd40588fa782861027b6b6K.png\" slate-data-type=\"image\"\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color:rgb(0, 112, 192);font-size:18px\"\u003e5 Battery Discharge Power Mode\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style='font-family:\"times new roman\", times, serif'\u003e\u003cspan style=\"font-size:16px\"\u003eNew upgraded firmware enable battery or solar limiter current and power model.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cdiv\u003e\u003cspan style='font-family:\"times new roman\", times, serif'\u003e\u003cspan style=\"font-size:16px\"\u003eUser can set the maximum output power of inverter , this can make the inverter work at cooler contition as user want and extend the lifespan of the inverter .\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style='font-family:\"times new roman\", times, serif'\u003e\u003cspan style=\"font-size:16px\"\u003eUser can set kick in\/off voltage of the inverter which can flexible using with battery bank depend on users mind and can prevent battery bank from over discharged .\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\u003ch3\u003e\u003cspan style=\"font-size:18px\"\u003e\u003cspan style=\"color:rgb(0, 112, 192)\"\u003e6 Limiter Module Specification\u003c\/span\u003e\u003c\/span\u003e\u003c\/h3\u003e\u003cdiv\u003e\n\u003cp\u003e1. Clamp sensor- Max 100A\u003c\/p\u003e\n\u003cp\u003e2. Wattmeter- Max 9999w\u003c\/p\u003e\n\u003cp\u003e3. Terminal Block-Max 20A\u003c\/p\u003e\n\u003cp\u003e4. Receptacle- max 2000w\u003c\/p\u003e\n\u003cp\u003e5. Clamp sensor signal- 5v AC max mA\u003c\/p\u003e\n\u003cp\u003e6. DC signal Cable- 5v DC, max mA\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\u003cimg src=\"http:\/\/ae01.alicdn.com\/kf\/HTB13I2Nb0zJ8KJjSspkq6zF7VXaq.jpg?size=79027\u0026amp;height=800\u0026amp;width=800\u0026amp;hash=6065b0e8b3ddf6b311f184bf1531d150\" slate-data-type=\"image\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cp\u003e\u003cbr\u003e\u003cspan style=\"color:rgb(196, 81, 0);font-size:12pt;font-family:Arial-BoldItalicMT\"\u003e\u003cstrong\u003eInstalling Sunshine Grid Tie Power System to Three Phases Utility Grid. (Especially for 2000W inverter model to work n United States with 240V three phase Utility power) \u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"color:rgba(104,188,0,255);font-size:12pt;font-family:Arial-BoldItalicMT\"\u003e\u003cstrong\u003ewith model: 2000W-T\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cdiv\u003e\n\u003cspan style=\"color:rgb(35, 31, 32);font-size:12pt;font-family:ArialMT\"\u003eWhen the Capacity of the Grid Tie Power System is large, install all the power systems to one phase of the utility grid is not reasonable. May be this will cause an unbalance of the three phases of the utility grid.\u003cbr\u003eInthissection, we will explain how to install a Sunshine Power System to three phases of the utility grid separately to balance the fed power.\u003cbr\u003eFor example, install a 3KW grid tie power system to a three phases utility grid. The diagram is shown in Fig.8, we separate the 3KW power system to three power system units, every unit has 1KW power. Connecting every system unit to a diﬀerent phase can balance all grid tie power to three phases of the utility grid. Follow this way, you can install a more large g rid tie power system to three phases, just separate the whole power system to three equal power system units.\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/S961de38b998343468abbd833df59c885l.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style='background-color:rgb(201, 231, 255);color:rgb(43, 50, 59);font-size:14px;font-family:OpenSans, \"Helvetica Neue\", Helvetica, Tahoma, Arial, \"PingFang SC\", \"Microsoft YaHei\"'\u003eFor the 2000w on grid tie solar inverter model, it is only with DC 45-90v input to AC 220-240v single phase output, since the 240v AC voltage in US is 3phase type, so the inverter ac output needs to be connected with one of the hotline (A, B or C) as the above connection picture\u003c\/span\u003e\u003c\/p\u003e","brand":"East Supplier Platform","offers":[{"title":"1000W \/ 110-120V \/ United States|45-90V","offer_id":48342736306399,"sku":"1005008259549754-1000W-110-120V-United States-45-90V","price":524.08,"currency_code":"USD","in_stock":true},{"title":"1000W \/ 110-120V \/ United States|22-65V","offer_id":48342736339167,"sku":"1005008259549754-1000W-110-120V-United States-22-65V","price":524.08,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0503\/6412\/1244\/files\/S362df4271f7746b9a5aefcd023245e5ea.webp?v=1767490722","url":"https:\/\/eastsupplier.co.uk\/ja\/products\/1kw-2kw-solar-grid-tie-inverter-for-solar-panel-battery-1000w-2000w-limiter-for-pv-power-dc-22-65v45-90v-ac-110v-120v-220v-230v","provider":"EastSupplier Platform","version":"1.0","type":"link"}